βOH-2C-B Analytical Pellets consist of high-purity β-Hydroxy-2C-B uniformly compressed into standardized analytical substrates. This specialized semi-synthetic substituted phenethylamine derivative serves as a critical reference standard for advanced scientific investigation into serotonergic signaling pathways, receptor kinetics, and structure-activity relationships (SARs).
Supplied in a compressed pellet format, this product is specifically engineered for laboratories requiring precise, reproducible extraction of milligram-quantity compounds into analytical solvents. It eliminates the static loss, environmental degradation, and weighing errors associated with handling raw microgram/milligram powders, ensuring highly accurate molar concentrations for quantitative in vitro workflows.
Key Features & Quality Assurance
- Precise Nominal Load: Each standardized pellet contains a verified 60mg load of active compound, ensuring consistent and reproducible extraction yields for stock solution preparation.
- Exceptional Analytical Purity (≥98%): Manufactured from selected high-grade precursors and rigorously verified via HPLC and GC-MS to ensure reliable baseline data.
- Optimized Stability: Compressed and packaged in light-proof, airtight containers with desiccant to prevent oxidative degradation and ensure extended archival shelf life.
- Rapid Dissolution: Engineered for rapid and complete dissolution in polar organic solvents (e.g., methanol, ethanol, DMSO) for immediate in vitro assay preparation.
Primary Research Applications
- Receptor Binding Assays: In vitro evaluation of ligand affinity and modulatory effects at specific serotonergic receptor subtypes, particularly 5-HT2A and 5-HT2C.
- Comparative Structure-Activity Relationship (SAR) Studies: Analytical comparison with classical 2C-series analogs to map the pharmacological impact of the β-hydroxy substitution on receptor binding kinetics.
- Forensic & Analytical Reference: Utilized as a certified calibration standard for method validation, limit of detection (LOD) testing, and extraction protocol standardization in toxicological laboratories.
- In Vitro Metabolic Profiling: Investigation of enzymatic degradation pathways and metabolic stability in controlled microsomal models.
Technical Specifications
| Active Compound | β-Hydroxy-2C-B (βOH-2C-B) |
| Molecular Formula (Freebase) | C₁₀H₁₄BrNO₃ |
| Molar Mass (Freebase) | ~273.13 g/mol |
| Physical Format | Compressed analytical pellet, ~60mg nominal weight |
| Purity | ≥98% (HPLC & GC-MS Verified) |
| Solubility | Freely soluble in methanol, ethanol, and DMSO |
Handling & Stability Considerations
- Light & Moisture Sensitivity: Phenethylamine derivatives are prone to photodegradation and hydrolytic breakdown. Store strictly in the original airtight, light-proof packaging with desiccant.
- Temperature Control: Maintain optimal stability by storing in a cool, dry environment (2–8°C recommended for long-term archival).
- Controlled Environment: Handle exclusively in a professional, ventilated laboratory setting. Processing under a certified fume hood is mandatory during solvent extraction to prevent aerosol exposure.
- Mandatory PPE: Always utilize appropriate Personal Protective Equipment, including a laboratory coat, chemical-resistant nitrile gloves, and safety glasses.
- Access Control: Store strictly in a secure, access-controlled laboratory environment, restricted to authorized scientific personnel only.
- In Vitro Concentration Guidelines: For cellular receptor assays, typical working concentrations require careful optimization in the micromolar (µM) range, prepared via precise solvent extraction of the pellets.
- ⚠️ Critical Warning: This product is an analytical reference standard only. It is NOT approved, tested, or intended for human or animal consumption, therapeutic use, or household application.
Frequently Asked Questions (FAQ)
Why use an analytical pellet instead of raw powder?
Handling raw phenethylamine powders is highly susceptible to static loss, environmental degradation, and weighing errors. The standardized 60mg pellet provides a precise, uniform mass for reproducible solvent extraction protocols, ensuring accurate molar concentrations for in vitro assays.
How should this be prepared for LC-MS/GC-MS analysis?
The pellet should be submerged in a precise, measured volume of HPLC-grade methanol or acetonitrile, agitated gently to facilitate complete extraction of the active compound, and then filtered through a 0.22 µm PTFE syringe filter prior to chromatographic injection.
Is this product suitable for biological administration?
Absolutely not. This product is strictly intended for in vitro analytical and biochemical assays in controlled laboratory environments. Any form of biological administration is strictly prohibited and falls entirely outside the intended scientific use of this reference standard.
What is the regulatory status of this compound?
Regulatory status varies significantly by jurisdiction. Substituted phenethylamines are frequently subject to strict controlled substance legislation or analogue acts. It is permitted solely for authorized scientific research. The purchaser is solely responsible for verifying compliance and possessing any required institutional permits prior to ordering.